CVE-2017-5574 (genixcms)
SQL injection vulnerability in register.php in GeniXCMS before 1.0.0 allows unauthenticated users to execute arbitrary SQL commands via the activation parameter.
Source: CVE-2017-5574 (genixcms)
CVE-2017-5574 (genixcms)
SQL injection vulnerability in register.php in GeniXCMS before 1.0.0 allows unauthenticated users to execute arbitrary SQL commands via the activation parameter.
Source: CVE-2017-5574 (genixcms)
CVE-2017-5575 (genixcms)
SQL injection vulnerability in inc/lib/Options.class.php in GeniXCMS before 1.0.0 allows remote attackers to execute arbitrary SQL commands via the modules parameter.
Source: CVE-2017-5575 (genixcms)
CVE-2016-10156 (systemd)
A flaw in systemd v228 in /src/basic/fs-util.c caused world writable suid files to be created when using the systemd timers features, allowing local attackers to escalate their privileges to root. This is fixed in v229.
Source: CVE-2016-10156 (systemd)
CVE-2016-10102 (automize)
hitek.jar in Hitek Software’s Automize uses weak encryption when encrypting SSH/SFTP and Encryption profile passwords. This allows an attacker to retrieve the encrypted passwords from sshProfiles.jsd and encryptionProfiles.jsd and decrypt them to recover cleartext passwords. All 10.x up to and including 10.25 and all 11.x up to and including 11.14 are verified to be affected.
Source: CVE-2016-10102 (automize)
CVE-2016-9870
EMC Isilon OneFS 8.0.0.0, EMC Isilon OneFS 7.2.1.0 – 7.2.1.2, EMC Isilon OneFS 7.2.0.x, EMC Isilon OneFS 7.1.1.0 – 7.1.1.10, and EMC Isilon OneFS 7.1.0.x is affected by an LDAP injection vulnerability that could potentially be exploited by a malicious user to compromise the system.
Source: CVE-2016-9870
CVE-2017-5544
An issue was discovered on FiberHome Fengine S5800 switches V210R240. An unauthorized attacker can access the device’s SSH service, using a password cracking tool to establish SSH connections quickly. This will trigger an increase in the SSH login timeout (each of the login attempts will occupy a connection slot for a longer time). Once this occurs, legitimate login attempts via SSH/telnet will be refused, resulting in a denial of service; you must restart the device.
Source: CVE-2017-5544
CVE-2016-10104
Information Disclosure can occur in sshProfiles.jsd in Hitek Software’s Automize because of the Read attribute being set for Users. This allows an attacker to recover encrypted passwords for SSH/SFTP profiles. Verified in all 10.x versions up to and including 10.25, and all 11.x versions up to and including 11.14.
Source: CVE-2016-10104
CVE-2016-8213
EMC Documentum WebTop Version 6.8, prior to P18 and Version 6.8.1, prior to P06; and EMC Documentum TaskSpace version 6.7SP3, prior to P02; and EMC Documentum Capital Projects Version 1.9, prior to P30 and Version 1.10, prior to P17; and EMC Documentum Administrator Version 7.0, Version 7.1, and Version 7.2 prior to P18 contain a Stored Cross-Site Scripting Vulnerability that could potentially be exploited by malicious users to compromise the affected system.
Source: CVE-2016-8213
CVE-2017-5539
The patch for directory traversal (CVE-2017-5480) in b2evolution version 6.8.4-stable has a bypass vulnerability. An attacker can use ../ to bypass the filter rule. Then, this attacker can exploit this vulnerability to delete or read any files on the server. It can also be used to determine whether a file exists.
Source: CVE-2017-5539
CVE-2017-5553
Cross-site scripting (XSS) vulnerability in plugins/markdown_plugin/_markdown.plugin.php in b2evolution before 6.8.5 allows remote authenticated users to inject arbitrary web script or HTML via a javascript: URL.
Source: CVE-2017-5553