CVE-2017-11157

CVE-2017-11157

Multiple untrusted search path vulnerabilities in installer in Synology Cloud Station Backup before 4.2.5-4396 on Windows allows local attackers to execute arbitrary code and conduct DLL hijacking attack via a Trojan horse (1) shfolder.dll, (2) ntmarta.dll, (3) secur32.dll or (4) dwmapi.dll file in the current working directory.

Source: CVE-2017-11157

CVE-2017-12069

CVE-2017-12069

An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions < V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions < V14 SP1), SIMATIC NET PC Software, and SIMATIC IT Production Suite. By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system to access various resources chosen by the attacker.

Source: CVE-2017-12069

CVE-2016-5001

CVE-2016-5001

This is an information disclosure vulnerability in Apache Hadoop before 2.6.4 and 2.7.x before 2.7.2 in the short-circuit reads feature of HDFS. A local user on an HDFS DataNode may be able to craft a block token that grants unauthorized read access to random files by guessing certain fields in the token.

Source: CVE-2016-5001

CVE-2017-9945

CVE-2017-9945

In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions < V2.1.3), a Denial-of-Service condition could be induced by a specially crafted PROFINET DCP packet sent as a local Ethernet (Layer 2) broadcast. The affected component requires a manual restart via the main device to recover.

Source: CVE-2017-9945

CVE-2017-12734

CVE-2017-12734

A vulnerability has been identified in Siemens LOGO! devices before V1.81.2. An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.

Source: CVE-2017-12734

CVE-2017-12704

CVE-2017-12704

A heap-based buffer overflow issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. Researchers have identified multiple vulnerabilities where there is a lack of proper validation of the length of user-supplied data prior to copying it to the heap-based buffer, which could allow an attacker to execute arbitrary code under the context of the process.

Source: CVE-2017-12704