CVE-2017-12736

CVE-2017-12736

A vulnerability has been identified in the following Siemens products: RUGGEDCOM ROS for RSL910 devices: All versions < ROS v5.0.1, RUGGEDCOM ROS for all other devices: All versions < ROS v4.3.4, SCALANCE XB-200/XC-200/XP-200/XR300-WG: All versions >= v3.0, SCALANCE XR-500/XM-400: All versions >= v6.1. After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to write to the device under certain conditions, potentially allowing users located in the adjacent network of the targeted device to perform unauthorized administrative actions.

Source: CVE-2017-12736

CVE-2017-12741

CVE-2017-12741

A vulnerability has been identified in the following Siemens industrial products: SIMATIC S7-200 Smart: All versions < V2.03.01, SIMATIC S7-400 PN V6: All versions < V6.0.6, SIMATIC S7-400 H V6: All versions < 6.0.8, SIMATIC S7-400 PN/DP V7: All versions, SIMATIC S7-410 V8: All versions, SIMATIC S7-300: All versions, SIMATIC S7-1200: All versions, SIMATIC S7-1500: All versions < 2.0, SIMATIC S7-1500 Software Controller: All versions < 2.0, SIMATIC WinAC RTX 2010 incl. F: All versions, SIMATIC ET 200AL: All versions, SIMATIC ET 200ecoPN: All versions, SIMATIC ET 200M: All versions, SIMATIC ET 200MP: All versions, SIMATIC ET 200pro: All versions, SIMATIC ET 200S: All versions, SIMATIC ET 200SP: All versions, DK Standard Ethernet Controller: All versions, EK-ERTEC 200P: All versions < V4.5, EK-ERTEC 200 PN IO: All versions, SIMOTION D: All versions < V5.1 HF1, SIMOTION C: All versions < V5.1 HF1, SIMOTION P: All versions < V5.1 HF1, SINAMICS DCM: All versions, SINAMICS DCP: All versions, SINAMICS G110M / G120(C/P/D) w. PN: All versions < V4.7 SP9 HF1, SINAMICS G130 and G150: All versions, SINAMICS S110 w. PN: All versions, SINAMICS S120: All versions, SINAMICS S150 V4.7 and V4.8: All versions, SINAMICS V90 w. PN: All versions, SINUMERIK 840D sl: All versions, SIMATIC Compact Field Unit: All versions, SIMATIC PN/PN Coupler: All versions, SIMOCODE pro V PROFINET: All versions, SIRIUS Soft starter 3RW44 PN: All versions. Specially crafted packets sent to port 161/UDP could cause a Denial-of-Service condition. The affected devices must be restarted manually.

Source: CVE-2017-12741

CVE-2017-13876

CVE-2017-13876

An issue was discovered in certain Apple products. iOS before 11.2 is affected. macOS before 10.13.2 is affected. tvOS before 11.2 is affected. watchOS before 4.2 is affected. The issue involves the "Kernel" component. It allows attackers to execute arbitrary code in a privileged context or cause a denial of service (memory corruption) via a crafted app.

Source: CVE-2017-13876

CVE-2017-13903

CVE-2017-13903

An issue was discovered in certain Apple products. iOS before 11.2.1 is affected. tvOS before 11.2.1 is affected. The issue involves the "HomeKit" component. It allows remote attackers to modify the application state by leveraging incorrect message handling, as demonstrated by use of an Apple Watch to obtain an encryption key and unlock a door.

Source: CVE-2017-13903