CVE-2018-10594

CVE-2018-10594

Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.

Source: CVE-2018-10594

CVE-2018-3760

CVE-2018-3760

There is an information leak vulnerability in Sprockets. Versions Affected: 4.0.0.beta7 and lower, 3.7.1 and lower, 2.12.4 and lower. Specially crafted requests can be used to access files that exists on the filesystem that is outside an application’s root directory, when the Sprockets server is used in production. All users running an affected release should either upgrade or use one of the work arounds immediately.

Source: CVE-2018-3760

CVE-2018-12711

CVE-2018-12711

An XSS issue was discovered in the language switcher module in Joomla! 1.6.0 through 3.8.8 before 3.8.9. In some cases, the link of the current language might contain unescaped HTML special characters. This may lead to reflective XSS via injection of arbitrary parameters and/or values on the current page URL.

Source: CVE-2018-12711

CVE-2018-4861

CVE-2018-4861

A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could potentially read and download arbitrary files from the device’s file system. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Source: CVE-2018-4861

CVE-2018-1072

CVE-2018-1072

ovirt-engine before version ovirt 4.2.2 is vulnerable to an information exposure through log files. When engine-backup was run with one of the options "–provision*db", the database username and password were logged in cleartext. Sharing the provisioning log might inadvertently leak database passwords.

Source: CVE-2018-1072

CVE-2018-11448

CVE-2018-11448

A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a stored Cross-Site Scripting (XSS) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires that the attacker has access to the web interface of an affected device. The attacker must be authenticated as administrative user on the web interface. Afterwards, a legitimate user must access the web interface. A successful attack could allow an attacker to execute malicious code in the browser of a legitimate user. At the time of advisory publication no public exploitation of this security vulnerability was known.

Source: CVE-2018-11448

CVE-2018-4860

CVE-2018-4860

A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Source: CVE-2018-4860