CVE-2018-4846

CVE-2018-4846

A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). A factory account with hardcoded password might allow attackers access to the device over port 5900/tcp. Successful exploitation requires no user interaction or privileges and impacts the confidentiality, integrity, and availability of the affected device. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.

Source: CVE-2018-4846

CVE-2018-4845

CVE-2018-4845

A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). Remote attackers with either local or remote credentialed access to the "Remote View" feature might be able to elevate their privileges, compromising confidentiality, integrity, and availability of the system. No special skills or user interaction are required to perform this attack. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.

Source: CVE-2018-4845

CVE-2018-1000610

CVE-2018-1000610

A exposure of sensitive information vulnerability exists in Jenkins Configuration as Code Plugin 0.7-alpha and earlier in DataBoundConfigurator.java, Attribute.java, BaseConfigurator.java, ExtensionConfigurator.java that allows attackers with access to Jenkins log files to obtain the passwords configured using Configuration as Code Plugin.

Source: CVE-2018-1000610

CVE-2017-7658

CVE-2017-7658

In Eclipse Jetty Server, versions 9.2.x and older, 9.3.x (all non HTTP/1.x configurations), and 9.4.x (all HTTP/1.x configurations), when presented with two content-lengths headers, Jetty ignored the second. When presented with a content-length and a chunked encoding header, the content-length was ignored (as per RFC 2616). If an intermediary decided on the shorter length, but still passed on the longer body, then body content could be interpreted by Jetty as a pipelined request. If the intermediary was imposing authorization, the fake pipelined request would bypass that authorization.

Source: CVE-2017-7658

CVE-2018-1000607

CVE-2018-1000607

A arbitrary file write vulnerability exists in Jenkins Fortify CloudScan Plugin 1.5.1 and earlier in ArchiveUtil.java that allows attackers able to control rulepack zip file contents to overwrite any file on the Jenkins master file system, only limited by the permissions of the user the Jenkins master process is running as.

Source: CVE-2018-1000607

CVE-2018-1000603

CVE-2018-1000603

A exposure of sensitive information vulnerability exists in Jenkins Openstack Cloud Plugin 2.35 and earlier in BootSource.java, InstancesToRun.java, JCloudsCleanupThread.java, JCloudsCloud.java, JCloudsComputer.java, JCloudsPreCreationThread.java, JCloudsRetentionStrategy.java, JCloudsSlave.java, JCloudsSlaveTemplate.java, LauncherFactory.java, OpenstackCredentials.java, OpenStackMachineStep.java, SlaveOptions.java, SlaveOptionsDescriptor.java that allows attackers with Overall/Read access to Jenkins to connect to an attacker-specified URL using attacker-specified credentials IDs obtained through another method, capturing credentials stored in Jenkins, and to cause Jenkins to submit HTTP requests to attacker-specified URLs.

Source: CVE-2018-1000603