CVE-2017-16349

CVE-2017-16349

An exploitable XML external entity vulnerability exists in the reporting functionality of SAP BPC. A specially crafted XML request can cause an XML external entity to be referenced, resulting in information disclosure and potential denial of service. An attacker can issue authenticated HTTP requests to trigger this vulnerability.

Source: CVE-2017-16349

CVE-2017-16347

CVE-2017-16347

An attacker could send an authenticated HTTP request to trigger this vulnerability in Insteon Hub running firmware version 1012. At 0x9d01e7d4 the value for the s_vol key is copied using strcpy to the buffer at 0xa0001700. This buffer is maximum 12 bytes large (this is the maximum size it could be, it is possible other global variables are stored between this variable and the next one that we could identify), sending anything longer will cause a buffer overflow.

Source: CVE-2017-16347

CVE-2017-16342

CVE-2017-16342

An attacker could send an authenticated HTTP request to trigger this vulnerability in Insteon Hub running firmware version 1012. At 0x9d01c254 the value for the s_vol_dim_delta key is copied using strcpy to the buffer at 0xa0000514. This buffer is 4 bytes large, sending anything longer will cause a buffer overflow.

Source: CVE-2017-16342

CVE-2017-16340

CVE-2017-16340

An attacker could send an authenticated HTTP request to trigger this vulnerability in Insteon Hub running firmware version 1012. At 0x9d01c0e8 the value for the s_dport key is copied using strcpy to the buffer at 0xa000180c. This buffer is 6 bytes large, sending anything longer will cause a buffer overflow.

Source: CVE-2017-16340

CVE-2017-16344

CVE-2017-16344

An attacker could send an authenticated HTTP request to trigger this vulnerability in Insteon Hub running firmware version 1012. At 0x9d01c2c8 the value for the s_url key is copied using strcpy to the buffer at 0xa0001a0c. This buffer is 16 bytes large, sending anything longer will cause a buffer overflow. The destination can also be shifted by using an sn_speaker parameter between "0" and "3".

Source: CVE-2017-16344

CVE-2018-1155

CVE-2018-1155

In SecurityCenter versions prior to 5.7.0, a cross-site scripting (XSS) issue could allow an authenticated attacker to inject JavaScript code into an image filename parameter within the Reports feature area. Properly updated input validation techniques have been implemented to correct this issue.

Source: CVE-2018-1155

CVE-2017-14444

CVE-2017-14444

An exploitable buffer overflow vulnerability exists in Insteon Hub running firmware version 1012. The HTTP server implementation incorrectly handles the URL parameter during a firmware update request, leading to a buffer overflow on a global section. An attacker can send an HTTP GET request to trigger this vulnerability.

Source: CVE-2017-14444

CVE-2017-16338

CVE-2017-16338

An attacker could send an authenticated HTTP request to trigger this vulnerability in Insteon Hub running firmware version 1012. At 0x9d01bad0 the value for the host key is copied using strcpy to the buffer at 0xa00016e0. This buffer is 32 bytes large, sending anything longer will cause a buffer overflow.

Source: CVE-2017-16338