CVE-2019-13028

CVE-2019-13028

An incorrect implementation of a local web server in eID client (Windows version before 3.1.2, Linux version before 3.0.3) allows remote attackers to execute arbitrary code (.cgi, .pl, or .php) or delete arbitrary files via a crafted HTML page. This is a product from the Ministry of Interior of the Slovak Republic.

Source: CVE-2019-13028

CVE-2019-10989

CVE-2019-10989

In WebAccess/SCADA Versions 8.3.5 and prior, multiple heap-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. Note: A different vulnerability than CVE-2019-10991.

Source: CVE-2019-10989

CVE-2019-10964

CVE-2019-10964

In Medtronic MinMed 508 and Medtronic Minimed Paradigm Insulin Pumps, Versions, MiniMed 508 pump ? All versions, MiniMed Paradigm 511 pump ? All versions, MiniMed Paradigm 512/712 pumps ? All versions, MiniMed Paradigm 712E pump?All versions, MiniMed Paradigm 515/715 pumps?All versions, MiniMed Paradigm 522/722 pumps ? All versions,MiniMed Paradigm 522K/722K pumps ? All versions, MiniMed Paradigm 523/723 pumps ? Software versions 2.4A or lower, MiniMed Paradigm 523K/723K pumps ? Software, versions 2.4A or lower, MiniMed Paradigm Veo 554/754 pumps ? Software versions 2.6A or lower, MiniMed Paradigm Veo 554CM and 754CM models only ? Software versions 2.7A or lower, the affected insulin pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.

Source: CVE-2019-10964

CVE-2019-10175

CVE-2019-10175

A flaw was found in the containerized-data-importer in virt-cdi-cloner, version 1.4, where the host-assisted cloning feature does not determine whether the requesting user has permission to access the Persistent Volume Claim (PVC) in the source namespace. This could allow users to clone any PVC in the cluster into their own namespace, effectively allowing access to other user’s data.

Source: CVE-2019-10175

CVE-2019-9843

CVE-2019-9843

In DiffPlug Spotless before 1.20.0 (library and Maven plugin) and before 3.20.0 (Gradle plugin), the XML parser would resolve external entities over both HTTP and HTTPS and didn’t respect the resolveExternalEntities setting. For example, this allows disclosure of file contents to a MITM attacker if a victim performs a spotlessApply operation on an untrusted XML file.

Source: CVE-2019-9843