CVE-2019-13933

CVE-2019-13933

A vulnerability has been identified in SCALANCE X-200RNA switch family (All versions), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.

Source: CVE-2019-13933

CVE-2019-13939

CVE-2019-13939

A vulnerability has been identified in Nucleus NET (All versions), Nucleus RTOS (All versions), Nucleus ReadyStart for ARM, MIPS, and PPC (All versions < V2017.02.2 with patch "Nucleus 2017.02.02 Nucleus NET Patch"), Nucleus SafetyCert (All versions), Nucleus Source Code (All versions), VSTAR (All versions). By sending specially crafted DHCP packets to a device, an attacker may be able to affect availability and integrity of the device. Adjacent network access, but no authentication and no user interaction is needed to conduct this attack. At the time of advisory publication no public exploitation of this security vulnerability was known.

Source: CVE-2019-13939

CVE-2019-18282

CVE-2019-18282

The flow_dissector feature in the Linux kernel 4.3 through 5.x before 5.3.10 has a device tracking vulnerability, aka CID-55667441c84f. This occurs because the auto flowlabel of a UDP IPv6 packet relies on a 32-bit hashmd value as a secret, and because jhash (instead of siphash) is used. The hashmd value remains the same starting from boot time, and can be inferred by an attacker. This affects net/core/flow_dissector.c and related code.

Source: CVE-2019-18282

CVE-2019-10940

CVE-2019-10940

A vulnerability has been identified in SINEMA Server (All versions < V14.0 SP2 Update 1). Incorrect session validation could allow an attacker with a valid session, with low privileges, to perform firmware updates and other administrative operations on connected devices. The security vulnerability could be exploited by an attacker with network access to the affected system. An attacker must have access to a low privileged account in order to exploit the vulnerability. An attacker could use the vulnerability to compromise confidentiality, integrity, and availability of the affected system and underlying components. At the time of advisory publication no public exploitation of this security vulnerability was known.

Source: CVE-2019-10940

CVE-2019-10934

CVE-2019-10934

A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Upd 4), TIA Portal V16 (All versions). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known.

Source: CVE-2019-10934

CVE-2020-7106

CVE-2020-7106

Cacti 1.2.8 has stored XSS in data_sources.php, color_templates_item.php, graphs.php, graph_items.php, lib/api_automation.php, user_admin.php, and user_group_admin.php, as demonstrated by the description parameter in data_sources.php (a raw string from the database that is displayed by $header to trigger the XSS).

Source: CVE-2020-7106