CVE-2021-33530

CVE-2021-33530

In Weidmueller Industrial WLAN devices in multiple versions an exploitable command injection vulnerability exists in encrypted diagnostic script functionality of the devices. A specially crafted diagnostic script file can cause arbitrary busybox commands to be executed, resulting in remote control over the device. An attacker can send diagnostic while authenticated as a low privilege user to trigger this vulnerability.

Source: CVE-2021-33530

CVE-2021-33537

CVE-2021-33537

In Weidmueller Industrial WLAN devices in multiple versions an exploitable remote code execution vulnerability exists in the iw_webs configuration parsing functionality. A specially crafted user name entry can cause an overflow of an error message buffer, resulting in remote code execution. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.

Source: CVE-2021-33537

CVE-2021-33538

CVE-2021-33538

In Weidmueller Industrial WLAN devices in multiple versions an exploitable improper access control vulnerability exists in the iw_webs account settings functionality. A specially crafted user name entry can cause the overwrite of an existing user account password, resulting in remote shell access to the device as that user. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.

Source: CVE-2021-33538

CVE-2021-33536

CVE-2021-33536

In Weidmueller Industrial WLAN devices in multiple versions an exploitable denial-of-service vulnerability exists in ServiceAgent functionality. A specially crafted packet can cause an integer underflow, triggering a large memcpy that will access unmapped or out-of-bounds memory. An attacker can send this packet while unauthenticated to trigger this vulnerability.

Source: CVE-2021-33536

CVE-2021-33542

CVE-2021-33542

Phoenix Contact Classic Automation Worx Software Suite in Version 1.87 and below is affected by a remote code execution vulnerability. Manipulated PC Worx or Config+ projects could lead to a remote code execution when unallocated memory is freed because of incompletely initialized data. The attacker needs to get access to an original bus configuration file (*.bcp) to be able to manipulate data inside. After manipulation the attacker needs to exchange the original file by the manipulated one on the application programming workstation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities. Automated systems in operation which were programmed with one of the above-mentioned products are not affected.

Source: CVE-2021-33542

CVE-2021-33535

CVE-2021-33535

In Weidmueller Industrial WLAN devices in multiple versions an exploitable format string vulnerability exists in the iw_console conio_writestr functionality. A specially crafted time server entry can cause an overflow of the time server buffer, resulting in remote code execution. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.

Source: CVE-2021-33535

CVE-2021-33534

CVE-2021-33534

In Weidmueller Industrial WLAN devices in multiple versions an exploitable command injection vulnerability exists in the hostname functionality. A specially crafted entry to network configuration information can cause execution of arbitrary system commands, resulting in full control of the device. An attacker can send various authenticated requests to trigger this vulnerability.

Source: CVE-2021-33534

CVE-2021-33533

CVE-2021-33533

In Weidmueller Industrial WLAN devices in multiple versions an exploitable command injection vulnerability exists in the iw_webs functionality. A specially crafted iw_serverip parameter can cause user input to be reflected in a subsequent iw_system call, resulting in remote control over the device. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.

Source: CVE-2021-33533