CVE-2021-27887

CVE-2021-27887

Cross-site Scripting (XSS) vulnerability in the main dashboard of Ellipse APM versions allows an authenticated user or integrated application to inject malicious data into the application that can then be executed in a victim’s browser. This issue affects: Hitachi ABB Power Grids Ellipse APM 5.3 version 5.3.0.1 and prior versions; 5.2 version 5.2.0.3 and prior versions; 5.1 version 5.1.0.6 and prior versions.

Source: CVE-2021-27887

CVE-2021-27196

CVE-2021-27196

Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce the attack, as well as the IP addresses of the different IEC 61850 access points (of IEDs/products), to force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only products with IEC 61850 interfaces. This issue affects: Hitachi ABB Power Grids Relion 670 Series 1.1; 1.2.3 versions prior to 1.2.3.20; 2.0 versions prior to 2.0.0.13; 2.1; 2.2.2 versions prior to 2.2.2.3; 2.2.3 versions prior to 2.2.3.2. Hitachi ABB Power Grids Relion 670/650 Series 2.2.0 versions prior to 2.2.0.13. Hitachi ABB Power Grids Relion 670/650/SAM600-IO 2.2.1 versions prior to 2.2.1.6. Hitachi ABB Power Grids Relion 650 1.1; 1.2; 1.3 versions prior to 1.3.0.7. Hitachi ABB Power Grids REB500 7.3; 7.4; 7.5; 7.6; 8.2; 8.3. Hitachi ABB Power Grids RTU500 Series 7.x version 7.x and prior versions; 8.x version 8.x and prior versions; 9.x version 9.x and prior versions; 10.x version 10.x and prior versions; 11.x version 11.x and prior versions; 12.x version 12.x and prior versions. Hitachi ABB Power Grids FOX615 (TEGO1) R1D02 version R1D02 and prior versions. Hitachi ABB Power Grids MSM 2.1.0 versions prior to 2.1.0. Hitachi ABB Power Grids GMS600 1.3.0 version 1.3.0 and prior versions. Hitachi ABB Power Grids PWC600 1.0 versions prior to 1.0.1.4; 1.1 versions prior to 1.1.0.1.

Source: CVE-2021-27196

CVE-2021-26845

CVE-2021-26845

Information Exposure vulnerability in Hitachi ABB Power Grids eSOMS allows unauthorized user to gain access to report data if the URL used to access the report is discovered. This issue affects: Hitachi ABB Power Grids eSOMS 6.0 versions prior to 6.0.4.2.2; 6.1 versions prior to 6.1.4; 6.3 versions prior to 6.3.

Source: CVE-2021-26845

CVE-2021-0467

CVE-2021-0467

In Chromecast bootROM, there is a possible out of bounds write due to an incorrect bounds check. This could lead to local escalation of privilege in the bootloader, with physical USB access, with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android SoCAndroid ID: A-174490700

Source: CVE-2021-0467

CVE-2021-21556

CVE-2021-21556

Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and T640 Server BIOS contain a stack-based buffer overflow vulnerability in systems with NVDIMM-N installed. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of Service, arbitrary code execution, or information disclosure in UEFI or BIOS Preboot Environment.

Source: CVE-2021-21556

CVE-2021-21555

CVE-2021-21555

Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and T640 Server BIOS contain a heap-based buffer overflow vulnerability in systems with NVDIMM-N installed. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of Service, arbitrary code execution, or information disclosure in UEFI or BIOS Preboot Environment.

Source: CVE-2021-21555

CVE-2021-21554

CVE-2021-21554

Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and, Dell Precision 7920 Rack Workstation BIOS contain a stack-based buffer overflow vulnerability in systems with Intel Optane DC Persistent Memory installed. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of Service, arbitrary code execution, or information disclosure in UEFI or BIOS Preboot Environment.

Source: CVE-2021-21554

CVE-2021-21557

CVE-2021-21557

Dell PowerEdge Server BIOS and select Dell Precision Rack BIOS contain an out-of-bounds array access vulnerability. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of service, arbitrary code execution, or information disclosure in System Management Mode.

Source: CVE-2021-21557