CVE-2022-2590

CVE-2022-2590

A race condition was found in the way the Linux kernel’s memory subsystem handled the copy-on-write (COW) breakage of private read-only shared memory mappings. This flaw allows an unprivileged, local user to gain write access to read-only memory mappings, increasing their privileges on the system.

Source: CVE-2022-2590

CVE-2022-2758

CVE-2022-2758

All versions of LS Industrial Systems (LSIS) Co. Ltd LS Electric PLCs and XG5000 PLC programming software are affected where passwords are not adequately encrypted during the communication process between the XG5000 software and the affected PLC. This would allow an attacker to identify and decrypt the affected PLC’s password by sniffing the traffic.

Source: CVE-2022-2758

CVE-2022-2759

CVE-2022-2759

Delta Electronics Delta Robot Automation Studio (DRAS) versions prior to 1.13.20 are affected by improper restrictions where the software processes an XML document that can contain XML entities with URIs that resolve to documents outside of the intended sphere of control, causing the product to embed incorrect documents into its output. This may allow an attacker to view sensitive documents and information on the affected host.

Source: CVE-2022-2759

CVE-2022-3028

CVE-2022-3028

A race condition was found in the Linux kernel’s IP framework for transforming packets (XFRM subsystem) when multiple calls to xfrm_probe_algs occurred simultaneously. This flaw could allow a local attacker to potentially trigger an out-of-bounds write or leak kernel heap memory by performing an out-of-bounds read and copying it into a socket.

Source: CVE-2022-3028

CVE-2022-30317

CVE-2022-30317

Honeywell Experion LX through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0055, there is a Honeywell Experion LX Control Data Access (CDA) EpicMo protocol with unauthenticated functionality issue. The affected components are characterized as: Honeywell Control Data Access (CDA) EpicMo (55565/TCP). The potential impact is: Firmware manipulation, Denial of service. The Honeywell Experion LX Distributed Control System (DCS) utilizes the Control Data Access (CDA) EpicMo protocol (55565/TCP) for device diagnostics and maintenance purposes. This protocol does not have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocol in question. An attacker capable of invoking the protocols’ functionalities could issue firmware download commands potentially allowing for firmware manipulation and reboot devices causing denial of service.

Source: CVE-2022-30317

CVE-2022-30318

CVE-2022-30318

Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service.

Source: CVE-2022-30318

CVE-2022-26330

CVE-2022-26330

Potential vulnerabilities have been identified in Micro Focus ArcSight Logger. The vulnerabilities could be remotely exploited resulting in Information Disclosure, or Self Cross-Site Scripting (XSS). This issue affects: Micro Focus ArcSight Logger versions prior to v7.2.2 version and prior versions.

Source: CVE-2022-26330

CVE-2022-1976

CVE-2022-1976

A flaw was found in the Linux kernel’s implementation of IO-URING. This flaw allows an attacker with local executable permission to create a string of requests that can cause a use-after-free flaw within the kernel. This issue leads to memory corruption and possible privilege escalation.

Source: CVE-2022-1976

CVE-2022-2004

CVE-2022-2004

AutomationDirect DirectLOGIC is vulnerable to a a specially crafted packet can be sent continuously to the PLC to prevent access from DirectSoft and other devices, causing a denial-of-service condition. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;

Source: CVE-2022-2004