CVE-2023-22407

CVE-2023-22407

An Incomplete Cleanup vulnerability in the Routing Protocol Daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows an adjacent, unauthenticated attacker to cause a Denial of Service (DoS). An rpd crash can occur when an MPLS TE tunnel configuration change occurs on a directly connected router. This issue affects: Juniper Networks Junos OS All versions prior to 18.4R2-S7; 19.1 versions prior to 19.1R3-S2; 19.2 versions prior to 19.2R3; 19.3 versions prior to 19.3R3; 19.4 versions prior to 19.4R3; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R2. Juniper Networks Junos OS Evolved All versions prior to 19.2R3-EVO; 19.3 versions prior to 19.3R3-EVO; 19.4 versions prior to 19.4R3-EVO; 20.1 versions prior to 20.1R3-EVO; 20.2 versions prior to 20.2R2-EVO.

Source: CVE-2023-22407

CVE-2023-22417

CVE-2023-22417

A Missing Release of Memory after Effective Lifetime vulnerability in the Flow Processing Daemon (flowd) of Juniper Networks Junos OS allows a network-based, unauthenticated attacker to cause a Denial of Service (DoS). In an IPsec VPN environment, a memory leak will be seen if a DH or ECDH group is configured. Eventually the flowd process will crash and restart. This issue affects Juniper Networks Junos OS on SRX Series: All versions prior to 19.3R3-S7; 19.4 versions prior to 19.4R2-S8, 19.4R3-S10; 20.2 versions prior to 20.2R3-S6; 20.3 versions prior to 20.3R3-S5; 20.4 versions prior to 20.4R3-S5; 21.1 versions prior to 21.1R3-S4; 21.2 versions prior to 21.2R3; 21.3 versions prior to 21.3R3; 21.4 versions prior to 21.4R2.

Source: CVE-2023-22417

CVE-2023-22408

CVE-2023-22408

An Improper Validation of Array Index vulnerability in the SIP ALG of Juniper Networks Junos OS on SRX 5000 Series allows a network-based, unauthenticated attacker to cause a Denial of Service (DoS). When an attacker sends an SIP packets with a malformed SDP field then the SIP ALG can not process it which will lead to an FPC crash and restart. Continued receipt of these specific packets will lead to a sustained Denial of Service. This issue can only occur when both below mentioned conditions are fulfilled: 1. Call distribution needs to be enabled: [security alg sip enable-call-distribution] 2. The SIP ALG needs to be enabled, either implicitly / by default or by way of configuration. To confirm whether SIP ALG is enabled on SRX, and MX with SPC3 use the following command: user@host> show security alg status | match sip SIP : Enabled This issue affects Juniper Networks Junos OS on SRX 5000 Series: 20.4 versions prior to 20.4R3-S5; 21.1 versions prior to 21.1R3-S4; 21.2 versions prior to 21.2R3-S3; 21.3 versions prior to 21.3R3-S3; 21.4 versions prior to 21.4R3-S2; 22.1 versions prior to 22.1R2-S2, 22.1R3; 22.2 versions prior to 22.2R3; 22.3 versions prior to 22.3R1-S1, 22.3R2. This issue does not affect Juniper Networks Junos OS versions prior to 20.4R1.

Source: CVE-2023-22408

CVE-2023-22409

CVE-2023-22409

An Unchecked Input for Loop Condition vulnerability in a NAT library of Juniper Networks Junos OS allows a local authenticated attacker with low privileges to cause a Denial of Service (DoS). When an inconsistent "deterministic NAT" configuration is present on an SRX, or MX with SPC3 and then a specific CLI command is issued the SPC will crash and restart. Repeated execution of this command will lead to a sustained DoS. Such a configuration is characterized by the total number of port blocks being greater than the total number of hosts. An example for such configuration is: [ services nat source pool TEST-POOL address x.x.x.0/32 to x.x.x.15/32 ] [ services nat source pool TEST-POOL port deterministic block-size 1008 ] [ services nat source pool TEST-POOL port deterministic host address y.y.y.0/24] [ services nat source pool TEST-POOL port deterministic include-boundary-addresses] where according to the following calculation: 65536-1024=64512 (number of usable ports per IP address, implicit) 64512/1008=64 (number of port blocks per Nat IP) x.x.x.0/32 to x.x.x.15/32 = 16 (NAT IP addresses available in NAT pool) total port blocks in NAT Pool = 64 blocks per IP * 16 IPs = 1024 Port blocks host address y.y.y.0/24 = 256 hosts (with include-boundary-addresses) If the port block size is configured to be 4032, then the total port blocks are (64512/4032) * 16 = 256 which is equivalent to the total host addresses of 256, and the issue will not be seen. This issue affects Juniper Networks Junos OS on SRX Series, and MX Series with SPC3: All versions prior to 19.4R3-S10; 20.1 version 20.1R1 and later versions; 20.2 versions prior to 20.2R3-S6; 20.3 versions prior to 20.3R3-S6; 20.4 versions prior to 20.4R3-S5; 21.1 versions prior to 21.1R3-S4; 21.2 versions prior to 21.2R3-S3; 21.3 versions prior to 21.3R3-S3; 21.4 versions prior to 21.4R3-S1; 22.1 versions prior to 22.1R2-S2, 22.1R3; 22.2 versions prior to 22.2R2.

Source: CVE-2023-22409

CVE-2023-22410

CVE-2023-22410

A Missing Release of Memory after Effective Lifetime vulnerability in the Juniper Networks Junos OS on MX Series platforms with MPC10/MPC11 line cards, allows an unauthenticated adjacent attacker to cause a Denial of Service (DoS). Devices are only vulnerable when the Suspicious Control Flow Detection (scfd) feature is enabled. Upon enabling this specific feature, an attacker sending specific traffic is causing memory to be allocated dynamically and it is not freed. Memory is not freed even after deactivating this feature. Sustained processing of such traffic will eventually lead to an out of memory condition that prevents all services from continuing to function, and requires a manual restart to recover. The FPC memory usage can be monitored using the CLI command "show chassis fpc". On running the above command, the memory of AftDdosScfdFlow can be observed to detect the memory leak. This issue affects Juniper Networks Junos OS on MX Series: All versions prior to 20.2R3-S5; 20.3 version 20.3R1 and later versions.

Source: CVE-2023-22410