CVE-2021-27381

CVE-2021-27381

A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)

Source: CVE-2021-27381

CVE-2021-25675

CVE-2021-25675

A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service.

Source: CVE-2021-25675

CVE-2021-25676

CVE-2021-25676

A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions >= V2.1 and < V2.1.3). Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the device will reboot automatically.

Source: CVE-2021-25676

CVE-2021-23357

CVE-2021-23357

All versions of package github.com/tyktechnologies/tyk/gateway are vulnerable to Directory Traversal via the handleAddOrUpdateApi function. This function is able to delete arbitrary JSON files on the disk where Tyk is running via the management API. The APIID is provided by the user and this value is then used to create a file on disk. If there is a file found with the same name then it will be deleted and then re-created with the contents of the API creation request.

Source: CVE-2021-23357

CVE-2021-25667

CVE-2021-25667

A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3), SCALANCE M-800 (All versions >= V4.3), SCALANCE S615 (All versions >= V4.3), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE X300WG (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XR500 (All versions < V6.2), SCALANCE Xx200 Family (All versions < V4.1). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could
allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution.

Successful exploitation requires the passive listening feature of the device to be active.

Source: CVE-2021-25667

CVE-2021-25674

CVE-2021-25674

A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a NULL pointer deference condition could cause the application to terminate unexpectedly and must be restarted to restore the service.

Source: CVE-2021-25674

CVE-2021-25673

CVE-2021-25673

A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, the application could enter an infinite loop, become unresponsive and must be restarted to restore the service.

Source: CVE-2021-25673